EN UG-020 Link 6 user guide r1.0
271
Remedy
Make sure the safety I/O channel associated with the external device is configured correctly.
Select the correct safety type from the safety type drop-down on the
Safety I/Os
page in
for the channel where the device is connected.
Why is the robot stuck in Reduced mode?
Condition
The robot is moving at Reduced speed. All
Safety
pages indicate the robot should be moving at
Normal speeds.
Cause
The robot is receiving a signal to operate at Reduced speed.
Remedy
Make sure no safety I/O channel is sending a signal to the robot to operate at Reduced speed.
Issues related to modes of operations
Examples of issues with modes of operation that you may have include modes being disabled
and modes that seem stuck.
Why is Manual mode disabled?
Condition
The arrows of the virtual joystick of Jog Angular and Jog Cartesian in
are grayed
out.
The
in Kortex Web App illuminates white.
Cause
The enabling device is not held in its center position.
Remedy
Procedure
• Make sure you are not pressing the enabling device all the way to the bottom.
• Make sure you are pressing the enabling device in its middle position.
Why can the robot not exit recovery mode?
Condition
The robot cannot exit Recovery mode. The wrist ring flashes yellow two times each second.
Cause
There are two situations where the robot remains in recovery mode.