ELS-304
5-12
Operations of Load Modes
5.11
Dynamic (DYNAMIC) Mode
In this mode, load current changes alternately between two
setup values according to the period of each load value.
This mode can be used along with CC, CV, CR, CP, EXT, or
SHORT mode.
(
1
)
Two values of load setting
There are two setting necessary, “CC1”, and “CC2”, in Dynamic mode.
Fig.5-11-1
Operation in DYNAMIC mode
“CC1” and “CC2” have the following parameters, which can be setup independently each
other.
・
Load value
You can setup these values same as in each mode selected
・
Effective time
from
10
μ
s to 60s (10
μ
s resolution)
・
Response speed (slew rate)
You can setup these values same as in each mode selected
・
The accuracy of the Effective time becomes coarser as the effective time becomes longer, even
though the resolution is not changed.
・
In the dynamic mode operation, trigger signals are outputted from the TRIG OUT output on
the front panel in the timing of this point where a circle is drawn in the Fig.5-11-1.
For more information, refer to
→
”
2.4
TRIG OUT
“.
Supplement
I
T
Load
Cuurent
Setting Period
SET(CC1)
SET(CC2)
TIME(msec)
Current(A)
TIME(CC1)
TIME(CC2)
RESP(CC1)
(A/usec)
RESP(CC2)
(A/usec)
Timing when trigger signal is outputted
from the TRIG OUT terminal
Содержание ELS-304
Страница 1: ...ELS 304 High SPEED Electronic Load OPERATION MANUAL Engineering Company SERIES ...
Страница 12: ...ELS 304 ...
Страница 22: ...ELS 304 2 8 Connections ...
Страница 50: ...ELS 304 6 4 Operations for Meas Modes ...
Страница 72: ...ELS 304 8 18 Programming Mode ...
Страница 76: ...ELS 304 9 4 Specifications ...
Страница 80: ......