194
Keysight M8070A Programming Guide
5
SCPI Command Reference
Description
This command enables/disables the inter symbol interference state.
This SCPI is applicable for M8041A, M8051A and M8062A.
Example
:SOUR:INT:ISYM 'M2.DataOut1', ON
[:SOURce]:INTerference:ISYMbol:MODE[?]
Syntax
[:SOURce]:INTerference:ISYMbol:MODE 'Identifier', <PONE | PTWO>
[:SOURce]:INTerference:ISYMbol:MODE? 'Identifier'
Input
Parameters
Identifier: 'M*.DataOut1', 'M*.DataOut2', or 'M*.DataOut'
Description
This command allows the user to adjust inter symbol interface trace via
one (no offset) or two point (variable offset).
Inter symbol interference mode must be set to one or two points; then
only, the value of frequency and insertion loss parameter can be changed.
This SCPI is applicable for M8041A, M8051A and M8062A.
Example
:SOUR:INT:ISYM:MODE 'M2.DataOut1', PTWO
[:SOURce]:INTerference:ISYMbol:FREQuency{1:2}[?]
Syntax
[:SOURce]:INTerference:ISYMbol:FREQuency1 'Identifier', <NRf>
[:SOURce]:INTerference:ISYMbol:FREQuency2 'Identifier', <NRf>
[:SOURce]:INTerference:ISYMbol:FREQuency1? 'Identifier'
[:SOURce]:INTerference:ISYMbol:FREQuency2? 'Identifier'
Input
Parameters
Identifier: 'M*.DataOut1', 'M*.DataOut2', or 'M*.DataOut'
Description
This command sets one or two discrete user definable frequencies f1 and
f2 of the inter symbol interference (ISI) trace. The mode has to be changed
to two points in order to use the second frequency.
This SCPI is applicable for M8041A, M8051A and M8062A.
Range
1GHz to 16GHz.
Example
:SOUR:INT:ISYM:FREQ1 'M2.DataOut1', 8.0e9