13 Cursors
To make cursor measurements / 194
Cursor Examples / 197
Cursors are horizontal and vertical markers that indicate X-axis values and Y-axis
values on a selected waveform source. You can use cursors to make custom
voltage, time, phase, or ratio measurements on oscilloscope signals.
Cursor information is displayed in the right-side information area.
Cursors are not always limited to the visible display. If you set a cursor, then pan
and zoom the waveform until the cursor is off screen, its value will not be changed.
It will still be there when you return to its original location.
X Cursors
X cursors are vertical dashed lines that adjust horizontally and can be used to
measure time (s), frequency (1/s), phase (°), and ratio (%).
The X1 cursor is the short-dashed vertical line, and the X2 cursor is the
long-dashed vertical line.
When used with the FFT math function as a source, the X cursors indicate
frequency.
In XY horizontal mode, the X cursors display channel 1 values (Volts or Amps).
The X1 and X2 cursor values for the selected waveform source are displayed in the
softkey menu area.
The difference between X1 and X2 (
Δ
X) and 1/
Δ
X are displayed in the Cursors box
in the right-side information area.
Y Cursors
Y cursors are horizontal dashed lines that adjust vertically and can be used to
measure Volts or Amps, dependent on the channel
Probe Units
setting, or they can
measure ratios (%). When math functions are used as a source, the measurement
units correspond to that math function.
Содержание DSO-X 2014A
Страница 1: ...Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide...
Страница 8: ...8 Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide...
Страница 60: ...60 Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide 2 Horizontal Controls...
Страница 68: ...68 Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide 3 Vertical Controls...
Страница 118: ...118 Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide 6 Digital Channels...
Страница 124: ...124 Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide 7 Serial Decode...
Страница 130: ...130 Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide 8 Display Settings...
Страница 168: ...168 Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide 10 Triggers...
Страница 176: ...176 Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide 11 Trigger Mode Coupling...
Страница 202: ...202 Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide 13 Cursors...
Страница 226: ...226 Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide 14 Measurements...
Страница 240: ...240 Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide 15 Mask Testing...
Страница 244: ...244 Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide 16 Digital Voltmeter...
Страница 256: ...256 Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide 17 Waveform Generator...
Страница 268: ...268 Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide 18 Save Recall Setups Screens Data...
Страница 274: ...274 Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide 19 Print Screens...
Страница 308: ...308 Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide 21 Web Interface...
Страница 326: ...326 Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide 22 Reference...
Страница 370: ...370 Keysight InfiniiVision 2000 X Series Oscilloscopes User s Guide 25 UART RS232 Triggering and Serial Decode...