General description
3.1
Use
Pumps from KESSEL AG pump domestic, municipal and industrial wastewater, faeces and sludges, including
those with a high share of solids and fibrous material, as well as all kinds of grey water. From small residential and
industrial buildings through to large pumping stations and sewage treatment plants. The pumps can pump abrasive
media such as surface water. With very abrasive fractions such as concrete gravel and sand in the medium, the
impeller and pump housing have to be protected against excessive wear and/or the maintenance interval has
to be shortened. In principle, the pumps are planned for use in specially designed KESSEL chamber systems
(engineering chambers). They may not be used in slurping operation. The minimum level of the pumping medium
must always be above the upper edge of the pump housing [1]. The motor housing must always be fully submerged
for use in S1 operation . In the operating mode S3 (30%), the pump can also be operated emerged, whereby the
minimum level must once again always be above the upper edge of the pump housing (1) . The pumping medium
temperature can be up to 40°C, temporarily up to a maximum of 60°C. The maximum density of the pumping
medium is 1040 kg/m³ and the pH value can be 6 - 11.
3.2
Types of use
The motor is designed for the operating mode S 1 (permanent operation) with a max. switching frequency of 15
switchings/hour. The hydraulics are suitable for permanent operation.
3.3
Design
The fully submersible unit consists of the motor, pump housing and the matching impeller.
All important components are generously dimensioned.
Handle
Type plate
Pump housing
Pressure port
Cable duct
Handle
Motor housing
Type plate
Pump housing
Pressure port
Cable duct
Suction connection
Type STF / STK
Type STZ
Motor housing
Fig. [4]
Fig. [5]
1
Type designation
15
Insulation class
2
Article number
16
Frequency
3
Hmax (max. pumping height)
17
Voltage
4
Hmin (min. pumping height)
18
Rated current
5
Qmax (max. pumping capacity)
19
Motor speed
6
Medium temperature
20
Operating capacitor
7
Weight
21
Starting capacitor
8
Protective rating
22
Capacity P1
9
Standard
23
Capacity P2
10
Model year (MM/YYYY)
24
Cos phi
11
Serial number
25
EX certificate number
12
BauPVO testing laboratory
26
EX-text laboratory
13
Motor type
27
EX-marking
14
Mode of operation
28
EX-i circuit data