55
ServoA
Operation Manual
Diagnostics
ID no.: LDS-O-SA-EN-202103
Display
Software
code
Error
number
Error description
E-PLC
215
Interal error: unkown code. During execution of the program an
unknown order is called, does not exist in software version.
216
Interal error: no code available. Jump to unknown address or
unidentified data loss.
1. Process control is in waiting position and shows the faulty
program line
2. Correct the process program resp. faulty program line
217
Dividing by zero occurs in the process program
1. Process control is in waiting position and shows the faulty
program line
2. Correct the process program resp. faulty program line
218
Program download not possible, program is password protected
1. Unlock password protection und download your new program
again
2. No program access possible without correct password
221
Cycle time of process control exceeded
Increase the cycle time via parameter 453-PLCIR
223
Error in indicated addressing
1. Check settings of used index
2. Process control is in waiting position and shows the faulty
program line
3. Correct the process program resp. faulty program line
224
Error during program selection: No such program
Check program selection via index in variable
225
Input values out of range, please modify input values
226
PLC command not executable in this version
1. Process control is in waiting position and shows the faulty
program line
2. Correct the process program resp. faulty program line
E-SIO
The USB interface communication error
4
No RS485 field bus available or baud rate invalid
9
Watchdog to control communication via LustBus actuated
1. connection
2. Check busmaster or increase parameter SWDGT
3. Switch-off control (factory setting) via parameter SWDGT = 0
Display
Software code
Error
number
Error description
E-CAN
34
Node-Error
35
Error in initialization
36
Pdo object out of value range
37
Error in initialization of communication parameter
38
Final position memory overflow
39
Heartbeat error
40
Invalid CAN address
41
Insufficient memory for communication object storing
42
Guarding error in montoring of sync/pdo-objects
E-PLC
Internal PLC program execution error
0
Error in process control (PLC)
Please contact your service partner
210
Error actuated by process control via SET ERR = Mxx
211
Call under flow or over flow of internal PLC-stacks at
CALL or RET
1. Process control is in waiting position and shows the
faulty program line
2. Correct the process program resp. faulty program line
212
Error in writing of parameters of process control. Over-
flow of parameter buffering.
1. Wait in program via WAIT PAR, until a part of the
parameters is written
2. Process control is in waiting position and shows the
faulty program line
213
Error in writing of parameters of process control
Probably parameter does not exist, is not writeable or not
a field parameter
214
Error in reading of parameters of process control
Probably parameter does not exist or is not a field
parameter
Содержание ServoA SA52.0100
Страница 1: ...ServoA Operation Manual Servo controllers 2 2 A 20 A ...
Страница 6: ...6 ServoA Operation Manual ID no LDS O SA EN 202103 Space for your own notes ...
Страница 68: ...68 ServoA Operation Manual ID no LDS O SA EN 202103 Appendix Space for your own notes ...
Страница 69: ...69 ServoA Operation Manual ID no LDS O SA EN 202103 ...