10
ServoA
Operation Manual
ID no.: LDS-O-SA-EN-202103
Safety
U
V
N
L+
RB
L-
L3
L2
L1
U
V
N
L+
RB
L-
L3
L2
L1
During installation observe the following instructions:
• Always comply with the connection conditions and technical specifica
tions.
• Comply with the standards for electrical installations, such as regard
-
ingwire cross-section, grounding lead and ground connections.
•
Do not touch electronic components and contacts (electrostatic dis-
charge may destroy components).
• Take protection measures against electric shock according to IEC
60364-4-41:2005/AMD1, section 411.3. As a protection measure, use
additional protective equipotential bonding as described in Appendix D
of IEC 60364-4-41.
Table 1.1 Safety instructions
1.1.2
Warning symbols
The safety instructions detail the following hazard classes.
The hazard class defines the risk posed by failing to comply with the safety notice.
Warning symbols
General explanation
Hazard class to
ANSI Z 535
!
ATTENTION!
Misoperation may result in
damage to the drive or malfunctions.
Serious injury or damage to
property may occur.
DANGER FROM ElECTRICAl TEN
-
SiON!
improper behaviour may endan-
ger human life.
Death or serious injury will
occur.
DANGER FROM ROTATI NG PARTS!
Drive may start up automatically.
Death or serious injury will
occur.
Table 1.2 Explanations of warning symbols
1.2
intended use
ServoA drive controllers are components designed solely for vertical installation in sta
-
tionary electrical systems or machines.
When installed in machines the compliance with EN 60204 should be ascertained
before commissioning of the drive controller (e.g. start-up of intended use).
Commissioning (i.e. start-up of intended operation) is only permitted when strictly com
-
plying with the EMC Directive (2014/30/EU).
The ServoA conforms to the low Voltage Directive 2014/35/EU
If the drive controller is used for special applications, such as in areas subject to
explosion hazard, the required standards and regulations (e.g. EN 50014, “General
provisions”and EN 50018, “Flameproof housing”) must always be observed.
Repairs may only be carried out by authorized repair workshops. Unauthorized opening
and incorrect intervention could lead to death, physical injury or material damage. The
warranty provided by KEBA would thereby be rendered void.
NOTE:
Deployment of the drive controllers in non-stationary equipment is
classed as non-standard ambient conditions, and is permissible only by
special agreement.
Содержание ServoA SA52.0100
Страница 1: ...ServoA Operation Manual Servo controllers 2 2 A 20 A ...
Страница 6: ...6 ServoA Operation Manual ID no LDS O SA EN 202103 Space for your own notes ...
Страница 68: ...68 ServoA Operation Manual ID no LDS O SA EN 202103 Appendix Space for your own notes ...
Страница 69: ...69 ServoA Operation Manual ID no LDS O SA EN 202103 ...