17
ServoA Operation Manual
Electrical installation
ID no.: LDS-O-SA-EN-202103
No.
Designation
Function
D1, D2,
D3, D4,
D5, D6
7-segment
Device status display
H1
LED display
Power
PE
Protective conductor
connection
Protective condutor connection
T1, T2,
T3, T4
button
Service function, set parameter, save parameter, jog
X1
Power connection
Motor, braking resistor and connection for measurement of DC link
voltage
X2
Connection of control
supply Uv
24V supply voltage for control electronics of drive controller
X3
AC mains connection
Mains supply
X4a
Encoder interface
resolver, Hiperface, TTL, Sincos, include motor temperature monitor
X4b
Encoder interface
Endat2.1, SSI, TTL, sin/cos, for speed and position control
X5
Communication inter-
face (Fieldbus)
EtherCAT communication interface (SA5x.xxxx.xx3x)
CANopen communication interface (SA5x.xxxx.xx2x)
X6
USb port
Service port, connection to PC
X7
Master encoder and
encoder simulation
connection
Master encoder and encoder simulation connection
X8
Control terminals
Digital inputs/outputs,analog inputs, functional "torque off" request
include feedback
1) NOTE: The temperature sensor of the motor winding can be optionally connected via the encoder cables X4a or X4b.
Table 3.2 Key to connection diagram
3.4 Effective EMC installation
3.4.1 Interference immunity of drive controllers
ATTE NTION!
This is a restricted availability product in accordance with IEC
61800-3. This product may cause radio interference in domestic environ-
ments; in such cases the operator may need to take appropriate counter-
measures.
Conducted emission:
External radio frequency interference (rFI) suppression filters (EMCxxx) are available for
the drive controllers. With the measurement method specified and the external mains
filter, these drive controllers conform to the EMC product standard IEC 61800-3 for
"First environment" (residential C2) and "Second environment" (industrial C3).
radiated emission:
Size 1-4 drive controllers are conform to the EMC product standard IEC 61800-3 cat-
egory C2.
Size 5 drive controllers are conform to the EMC product standard IEC 61800-3 cat-
egory C3.
3.4.2 Specimen setup
The specimen setup presented on the following pages is intended to illustrate the key
measures necessary to ensure EMC-compatible setup.
NOTE:
The specimen setup merely presents a recommendation, and does not auto-
matically guarantee compliance with applicable EMC directives. The installer/
operator of a machine and/or item of plant must provide proof of compliance
with the protection targets stipulated in the standard.
!
Содержание ServoA SA52.0100
Страница 1: ...ServoA Operation Manual Servo controllers 2 2 A 20 A ...
Страница 6: ...6 ServoA Operation Manual ID no LDS O SA EN 202103 Space for your own notes ...
Страница 68: ...68 ServoA Operation Manual ID no LDS O SA EN 202103 Appendix Space for your own notes ...
Страница 69: ...69 ServoA Operation Manual ID no LDS O SA EN 202103 ...