A.2 ServoA ambient conditions
Ambient conditions
ServoA
Protection
IP00
Accident prevention regulations according to local regulations (in Germany e.g. BGV A3)
Mounting height
up to 1000 m above MSL, over 1000 m above MSL with pow-
er reduction (1 % per 100 m, max. 2000 m above MSL)
Pollution severity
2
Type of installation
Built-in unit, only for vertical installation in a switch cabinet
with min. IP4x protection
Environment
Far away from corrosive, flamnable gases, droplets of oil or
dust etc.
Table A.3 ServoA ambient conditions
Climatic conditions
ServoA
in transit
as per EN 61800-2, IEC 60721-3-2 class 2K3 1)
Temperature
-25 °C to +70 °C
Relative air humidity
95% at max. +40 °C
in storage
as per EN 61800-2, IEC 60721-3-1 class 1K3 and 1K4 2)
Temperature
-25 °C to +55 °C
Relative air humidity
5 to 95%
in operation
as per EN 61800-2, IEC 60721-3-3 class 3K3 3)
Temperature
-10 °C to +45 °C (4 kHz), up to 55 °C with power
reduction (2%/°C)
-10 °C to +40 °C (8, 16 kHz), up to 55 °C with
power reduction (2%/°C)
Relative air humidity
5 to 85% witout condensation
1) The absolute humidity is limited to max. 60 g/m³. This means, at 70 °C for example, that the relative humidity may only be
max. 40 %.
2) The absolute humidity is limited to max. 29 g/m³. So the maximum values for temperature and relative air humidity stipula-
ted in the table must not occur simultaneously.
3) The absolute humidity is limited to max. 25 g/m³. That means that the maximum values for temperature and relative air
humidity stipulated in the table must not occur simultaneously.
Table A.4 ServoA climatic conditions
Mechanical conditions
ServoA
Vibration
limit in
transit
as per EN 61800-2, IEC 60721-3-2 class 2M1
Frequency [Hz]
Amplitude [mm]
Acceleration [m/s
2
]
2 ≤ f < 9
3.5
not applicable
9 ≤ f < 200
not applicable
10
200 ≤ f < 500
not applicable
15
Shock limit
in transit
as per EN 61800-2, IEC 60721-2-2 class 2M1
Drop height of packed device max. 0.25 m
Vibration
limit of the
system1)
as per EN 61800-2, IEC 60721-3-3 class 3M1
Frequency [Hz]
Amplitude [mm]
Acceleration [m/s
2
]
2 ≤ f < 9
0.3
not applicable
9 ≤ f < 200
not applicable
1
1) NOTE: The devices are only designed for stationary use.
Table A.5 ServoA mechanical conditions
ATTENTION!
•
No continuous vibrations!
The drive controllers must not be installed in areas where they would be
permanently exposed to vibrations.
•
Observe cooling conditions!
Forced cooling by external air flow necessary. Air must be able to flow
unhindered through the device (air flow at least 1.2 m/s). If a temperature
cut-out occurs, the cooling conditions must be improved.
!
Содержание ServoA SA52.0100
Страница 1: ...ServoA Operation Manual Servo controllers 2 2 A 20 A ...
Страница 6: ...6 ServoA Operation Manual ID no LDS O SA EN 202103 Space for your own notes ...
Страница 68: ...68 ServoA Operation Manual ID no LDS O SA EN 202103 Appendix Space for your own notes ...
Страница 69: ...69 ServoA Operation Manual ID no LDS O SA EN 202103 ...