53
ServoA
Operation Manual
Diagnostics
ID no.: LDS-O-SA-EN-202103
Display
Software
code
Error
number
Error description
E-PAR
Parameter error
0
Invalid parameter setting
Correction of parameter setting or reset device to factory
setting
5
Value of one parameter is after start-up phase outside its value
range
1. Switch off/on device
2. Correct source data set (offline) and store in device
6
Error in first initialization of parameter list. One parameter can-
not reset to factory setting
1. Switch off/on device
2. Please contact your service provider if this error occurs
again
7
Error in initialization of a parameter with its stored adjustment
1. Switch off/on device
2. Correct source data set (offline) and store in device
8
Error while execution of internal operation panel parameter
access. One parameter could not be readed or written
Please contact your service provider if this error occurs again
19
Parameter cannot be modified via field bus while control is
active
1. Turn off control
2. change parameter value
47
Error in initialization of motor protection module
Check and change setting of the motor protection
55
Internal error in state machine of control
1. Switch off/on device
2. Please contact your service provider if this error occurs
again
100
Error in initialization of controller
Check and change setting of the control and motor parameters
101
Error in initialization of modulation
Check and change setting of switching frequency
102
Error in initialization of braking chopper
1. Switch off/on device
2. Please contact your service provider if this error occurs
again
Display
Software
code
Error
number
Error description
E-PAR
103
Error in initialization of current model
Check and change setting of control and motor parameter (motor
data set) (e.g. power class of motor and device are too different)
104
Error in initialization of current control
Check and change setting of control parameters CCG and
CCTLG
105
Error in initialization of speed calculation
Check and change setting of parameter ECTF
106
Error in initialization of speed controller
Check and change setting of of control parameters SCG, SCGFA
and SCTLG
107
Error in initialization of torque calculation
Check and change setting of motor parameter and limits (max.
torque and speed)
108
Error in initialization of position entry
Check and change setting of control parameter
109
Error in initialization of position controller
Check and change setting of control parameter
110
Error in initialization of V/f-characteristic line control
Check and change setting of control parameters (VN,VB,FN) and
motor parameter
111
Error in initialization of current-controlled operation
Check and change setting of control and motor parameter
112
Error in initialization of flux control in field waking range
Check and change setting of control and motor parameter
113
Error in initialization of power failure bridging
Check and change setting of control parameter
114
Error in initialization of current and voltage entry
1. Switch off/on device
2. Please contact your service provider if this error occurs again
115
Error in initialization of TTL-encoder evaluation encoder lines or
gear ratio not supported
Check and change setting of ecnoder (ECNO1, ECDE1,ECLN1)
116
Error in initialization of HTL-encoder evaluation encoder lines or
gear ratio not supported
Check and change setting of encoder (ECNO2, ECDE2,ECLN2)
Содержание ServoA SA52.0100
Страница 1: ...ServoA Operation Manual Servo controllers 2 2 A 20 A ...
Страница 6: ...6 ServoA Operation Manual ID no LDS O SA EN 202103 Space for your own notes ...
Страница 68: ...68 ServoA Operation Manual ID no LDS O SA EN 202103 Appendix Space for your own notes ...
Страница 69: ...69 ServoA Operation Manual ID no LDS O SA EN 202103 ...