54
ServoA
Operation Manual
ID no.: LDS-O-SA-EN-202103
Diagnostics
Display
Software
code
Error
number
Error description
131
Error in self commisioning (test signal generator)
132
Error in calibration of DC link voltage
145
Error evaluating q-format for parameter
149
Initialization of technology controller is incorrect
Check and change parameter values
154
Error in initialisation of torque observer, check corresponding
parameters
240
Error in initialisation of position controller,
reduce PCG
251
Error in factor group: result cannot be represented with 32Bits
E-FLT
Floating point calculation error
0
General error in floating point calculation
1. Switch off/on device
2. Please contact your service provider if this error occurs again
E-PWR
Incorrect test of power stage
4
Power pack not correctly identified
1. Switch off/on device
2. Please contact your service provider if this error occurs again
6
Same as above
44
Temperature sensor on heat sink possibly defective
1. Switch off/on device
2. Please contact your service provider if this error occurs again
E-EXT
Error in external device
1
Error in external device
Rectify error in external device
E-CAN
Error CAN-BUS
0
Error CAN-BUS
31
BUSOFF detected
32
Transmitting telegram not sent
33
Guarding error
Display
Software
code
Error
number
Error description
E-PAR
117
Error in initialization of SSI-interface and encoder evaluation
encoder lines or gear ratio not supported
Check and change setting of encoder (ECNO1, ECDE1,ECLN1)
and SSI
118
Error in initialization of enccoder configuration not allowed
combination of encoders (e.g. using one encoder as rotary
encoder and master encoder)
Check and change setting of encoder configuration
(CFSEC,CFPEC,CFREC, CFX7, CFX2)
119
Error in initialization of control\nabsurb value for main
inductivity(zero or negative)
Check motor data set (probable changing of parameter
MOLMF, as well as MOMC0 to MOMC4), confirmation of error
only after changing the parameter
120
Error in initialization of analog output
121
Error in initialization of analog inputs
Reduce selected value for scaling in % (+or-10V)
122
Invalid adjustment of parameter ECNPP (resolver pole pairs)
1. ECNPP should not be zero
2. Motor pole pair number MONPP has to be a multiple of
parameter ECNPP
123
Error in initialization of fault voltage compensation
124
Error in initialization of sensorless speed control (SFC)
125
Error in initialization of sensorless speed control (U/I-Modell)
126
Error in initialization of external AD-converter
127
Adjusted method of commutation finding is not supported
128
Error in initialization of GPOC fault correction method
129
Error in configuration of HTL-encoder.
HTL-encoder was adjusted but inputs FIS02 and FIS03 are not
set to HTL interpretation.
Adjust inputs FIS02 aud FIS03 to HTL-encoder in dialog Inputs.
130
Error during current controller tuning
1. Switch off/on device
2. Please contact your service provider if this error occurs
again
Содержание ServoA SA52.0100
Страница 1: ...ServoA Operation Manual Servo controllers 2 2 A 20 A ...
Страница 6: ...6 ServoA Operation Manual ID no LDS O SA EN 202103 Space for your own notes ...
Страница 68: ...68 ServoA Operation Manual ID no LDS O SA EN 202103 Appendix Space for your own notes ...
Страница 69: ...69 ServoA Operation Manual ID no LDS O SA EN 202103 ...