19
ServoA Operation Manual
Electrical installation
ID no.: LDS-O-SA-EN-202103
Detail 1: Motor cable
At the motor connection (X1) ServoA note the following points:
•
Secure one of the two supplied shield connection plates by the screw to the
mount on the top of the unit. Ensure the plate contacts across a wide area with
the heat sink of the ServoA and with the backing plate. Use a toothed ring.
•
Strip back the shield of the motor cable on the motor connection (X1) of the Ser-
voA as little as absolutely necessary.
•
Connect the motor cable shield across a wide area to the shield connection plate
by the clamp supplied.
NOTE:
ready made-up motor cables are available for KEbA servomotors. Fordetails
refer to the Servomotors order catalogue.
Figure 3.4 Specimen setup - Detail 1: Motor cable
X1
Detail 2: Control supply
At the control supply connection (X2):
•
Secure the second of the two supplied shield connection plates by the screw to
the mount on the bottom of the unit. Ensure the plate contacts across a wide area
with the heat sink of the ServoA and with the backing plate. Use a toothed ring.
•
Slot a shield tube over the control supply cable and strip it back only as short as
necessary before the control supply connection (X2).
•
Connect the shielding tube of the control supply cable across a wide area to the
shield connection plate by the clamp supplied.
Figure 3.5 Specimen setup - Detail 2: Control supply
X2
Содержание ServoA SA52.0100
Страница 1: ...ServoA Operation Manual Servo controllers 2 2 A 20 A ...
Страница 6: ...6 ServoA Operation Manual ID no LDS O SA EN 202103 Space for your own notes ...
Страница 68: ...68 ServoA Operation Manual ID no LDS O SA EN 202103 Appendix Space for your own notes ...
Страница 69: ...69 ServoA Operation Manual ID no LDS O SA EN 202103 ...