41
ServoA
Operation Manual
Electrical installation
ID no.: LDS-O-SA-EN-202103
Figure 3.21 RJ-45 interface
3.14.1.5 Connectors
The figure below shows the position of the connectors for the EtherCAT field bus system
on the ServoA device.
Link
Activity
EC OUT
EC IN
Figure 3.22 Device with EtherCAT option
Connection
Function
EC IN
RJ-45 socket – input
EC OUT
RJ-45 socket – output
Link/Activity status
Green LED
Function
Link
Off = No link
No connection to another bus user
On = Link
Connection to another bus user
Activity (L/A)
Off = No link
No connection to another bus user
On = Link
Connection to another bus user, no activity
Flashing = Activity
Data exchange active
3.14.1.6 Status Indicator