- 193 -
6. Description of Parameters
Function Code
Parameter Name
Setting Range
Default
F4-38
DI active mode
selection 1
0: High level active
1: Low level active
00000
Units position: DI1 active mode
Tens position: DI2 active mode
Hundreds position: DI3 active mode
Thousand position: DI4 active mode
Ten thousands position: DI5 active mode
F4-39
DI active mode
selection 2
0: High level active
1: Low level active
00000
Units position: DI6 active mode
Tens position: DI7 active mode
Hundreds position: DI8 active mode
Thousands position: DI9 active mode
Ten thousands position: DI10 active mode
6
Value
Function
Description
49
Deceleration DC
injection braking
When terminal set for this function becomes on, the AC drive
decelerates to DC injection braking 2 frequency threshold and
then switches over to DC injection braking state.
50
Clear running time
this time
When terminal set for this function becomes on, current running
time of the AC drive is cleared. This function must be supported
by F8-42 and F8-53.
51
Two-wire control/
Three-wire control
This function enables the AC drive to switch over between two-
wire control and three-wire control. If F4-11 is set to two-wire
control mode 1, the AC drive switches over to three-wire control
mode 1 when terminal set for this function becomes on.
52
Reverse running
prohibited
When terminal set for this function becomes on, reverse running
of the AC drive is prohibited. It is the same as function of F8-13.
53 to 59
Reserved
-
Function Code
Parameter Name
Setting Range
Default
F4-35
DI1 delay
0.0s to 3600.0s
0.0s
F4-36
DI2 delay
0.0s to 3600.0s
0.0s
F4-37
DI3 delay
0.0s to 3600.0s
0.0s
When state of DI terminals changes, these three function parameters set delay time of the
change. Now the drive supports delay function on DI1, DI2 and DI3 only.
These two function parameters set active mode of DI terminals.
●
0: High level active
If a high level voltage is applied to DI terminal, the DI signal will be seen as active. That is,
the DI terminal becomes active when being connected with COM, and inactive when being
disconnected from COM.
●
1: Low level active
If a low level voltage is applied to DI terminal, the DI signal will be seen as active. That is, the
DI terminal becomes active when being disconnected from COM, and inactive when being
connected with COM.
- 193 -
Содержание GT600-4T132G
Страница 1: ...GT600 AC Drive...
Страница 5: ......
Страница 86: ...5 Quick Setup 5 1 Get Familiar With Operating Panel 86 5 2 Setup Flowchart 87...
Страница 87: ......
Страница 100: ...5 Quick Setup 98 5...
Страница 280: ...8 Peripherals and Options 278 8...
Страница 306: ...12 303 11...
Страница 362: ......