6. Description of Parameters
- 183 -
Function Code
Parameter Name
Setting Range
Setting
Fd-00
Baud rate
0000 to 6039
Keep the same setting of
thousands position of this
parameter for the master
and slave.
A8-00
Point-point
communication
0: Disabled
1: Enabled
1
A8-01
Master or slave
selection
0: Master
1: Slave
0
F0-10
Max. frequency
5.00 to 500.00 Hz
50.00 Hz
Keep the same setting
of this parameter for the
master and slave.
F2-10
Digital setting of
torque upper limit in
speed control mode
0.0% to 200.0%
130.0%
You can use a relay for slave fault feedback or set tens position of A8-02 to
1 to send the salve fault information to the master via communication. Then
when the slave stops due to occurrence of a fault, the master stops running.
6
■
Installation
Figure 6-56 Connection of the master and slaves
CANH
■
Parameter Setting
●
Rigid connection
For master in speed control, perform the following settings. Note that only setting of
F2-10 can be modified.
CANL
COM
Master
Slave
Slave
Slave
MD38CAN1
MD38CAN1
MD38CAN1
MD38CAN1
GT600
DI COM
GT600
TA TB
GT600
TA TB
GT600
TA TB
Note
C
o
n
n
e
ct
a
t
e
rmi
n
a
l
re
si
st
o
r
C
o
n
n
e
ct
a
t
e
rmi
n
a
l r
e
si
st
o
r
Содержание GT600-4T132G
Страница 1: ...GT600 AC Drive...
Страница 5: ......
Страница 86: ...5 Quick Setup 5 1 Get Familiar With Operating Panel 86 5 2 Setup Flowchart 87...
Страница 87: ......
Страница 100: ...5 Quick Setup 98 5...
Страница 280: ...8 Peripherals and Options 278 8...
Страница 306: ...12 303 11...
Страница 362: ......