ACD320 user manual
Parameter Description
- 82-
F3.13
Current fault type
0
~
29
Record three recent fault types: 0 is no fault; 1~22 is 22 different kinds of fault. For
details,please see fault analysis.
Function Code
Name
Setting Range
Default
Value
F3.14
Operat ing frequency at
current fault
The output frequency
when current fault
happens
0.00Hz
F3.15
Output amperage at
current fault
The output amperage
when current fault
happens
0.0A
F3.16
Bus voltage at current
fault
The bus voltage when
current fault happens
0.0V
Function Code
Name
Setting Range
Default
Value
F3.17
Reserved
F3.18
Reserved
6.5 F4Application Function Parameters
Function Code
Name
Setting Range
Default
Value
F4.00
ACCELTime 2
0.1
~
3600.0s
10.0s
F4.01
DECEL Time 2
0.1
~
3600.0s
10.0s
Acceleration/Deceleration time can be chosen to be F0.08, F0.09 or above three time
settings. Their meanings are all the same; please refer to F0.08 and F0.09 related description.
TheAcceleration/Deceleration time 0-1 at inverter operation can be chosen through different
combination of multifunction digital input terminals.
Function Code
Name
Setting Range
Default
Value
F4.02
Frequency of JOG running
0.00
~
F0.04(maximum
frequency)
5.00Hz
F4.03
The acceleration time of
JOG running
0.1
~
3600.0s
10.0s
Содержание ACD320 Series
Страница 1: ......
Страница 26: ...ACD320user manual Installation and wiring 21 11 30KW...
Страница 120: ...ACD320user manual Fault Diagnosis and countermeasures 115 1 Inverting module protection U 01...
Страница 124: ...ACD320user manual Fault Diagnosis and countermeasures 119 8 Under voltage U 09 9 InverterOver Load U 10...
Страница 126: ...ACD320user manual Fault Diagnosis and countermeasures 121 13 Inverting Module Over Heat U 14 14 External Failure U 15...
Страница 160: ......