ACD320 user manual
Parameter Description
- 79-
factory value, and fine control relevant parameter.
Function Code
Name
Setting Range
Default
Value
F3.03
STOP function option
0: Keypad control valid
1: Keypad and terminal
control valid
2: Keypad and
communication
control valid
3: All controlmodes valid
0
This function code is to define the STOPstop function validity options.
Function Code
Name
Setting Range
Default
Value
F3.04
Reserved
0
Function Code
Name
Setting Range
Default
Value
F3.05
operation status display
parameter option
0-65535
1183
F3.06
Stop status display
parameter option
0-65535
207
F3.07
operation status display p
eferential option
0
~
15(0:invalid)
0
Operation status display:
Displayed Message
Code
F3.07
code
BIT0: Running frequency
1
1
BIT1: Setting frequency
2
******
BIT2: Output current
4
2
BIT3: Output voltage
8
3
BIT4: Running speed
16
4
BIT5: Output power
32
5
BIT6: Output torque
64
6
BIT7: DC bus voltage
128
7
Содержание ACD320 Series
Страница 1: ......
Страница 26: ...ACD320user manual Installation and wiring 21 11 30KW...
Страница 120: ...ACD320user manual Fault Diagnosis and countermeasures 115 1 Inverting module protection U 01...
Страница 124: ...ACD320user manual Fault Diagnosis and countermeasures 119 8 Under voltage U 09 9 InverterOver Load U 10...
Страница 126: ...ACD320user manual Fault Diagnosis and countermeasures 121 13 Inverting Module Over Heat U 14 14 External Failure U 15...
Страница 160: ......