![K&R ACD320 Series Скачать руководство пользователя страница 63](http://html1.mh-extra.com/html/kandr/acd320-series/acd320-series_user-manual_3099779063.webp)
ACD320 user manual
Parameter Description
- 58-
Value
F0.08
ACCELtime 1
0.1
~
3600.0s
10.0s
F0.09
DECEL time 1
0.1
~
3600.0s
10.0s
Acceleration time means the time t1 required for inverter to accelerate to the maximum
output frequency (F0.04) from 0Hz.
Deceleration time is the time t2 required for inverter to decelerate to 0Hz fromthe
maximumoutput frequency (F0.04).
It is indicated by following figure
Fig 6-1 Acceleration and Deceleration time diagram
When the set frequency is equal to the maximum frequency, the actual
Acceleration/Deceleration time are equal to the set Acceleration/Deceleration time.
When the set frequency is less than the maximum frequency, the actual
Acceleration/Deceleration time are less than the set Acceleration/Deceleration time.
Actual Acceleration /Deceleration time = set Acceleration/Deceleration time (set
frequency/max.frequency)
ACD320 series inverter has 2 groups ofAcceleration/Deceleration time.
1st group: F0.08, F0.09;
2nd group: F4.00, F4.01;
The Acceleration /Deceleration time can be chosen through multifunction digital input
terminal (F2 Group).
Содержание ACD320 Series
Страница 1: ......
Страница 26: ...ACD320user manual Installation and wiring 21 11 30KW...
Страница 120: ...ACD320user manual Fault Diagnosis and countermeasures 115 1 Inverting module protection U 01...
Страница 124: ...ACD320user manual Fault Diagnosis and countermeasures 119 8 Under voltage U 09 9 InverterOver Load U 10...
Страница 126: ...ACD320user manual Fault Diagnosis and countermeasures 121 13 Inverting Module Over Heat U 14 14 External Failure U 15...
Страница 160: ......