![K&R ACD320 Series Скачать руководство пользователя страница 45](http://html1.mh-extra.com/html/kandr/acd320-series/acd320-series_user-manual_3099779045.webp)
ACD320user manual
Function parameters list
- 40-
F1.05
Motor rated current 0.1
~
1000.0A
Set by
model
×
31
F1.06
Motor stator
resistance
0.001
~
65.535Ω
Set by
model
○
32
F1.07
Motor rotor
resistance
0.001
~
65.535Ω
Set by
model
○
33
F1.08
Motor stator/rotor
inductance
0.1
~
6553.5mH
Set by
model
○
34
F1.09
Mutual inductance
of motor
stator/rotor
0.1
~
6553.5mH
Set by
model
○
35
F1.10
No-load current
0.01
~
655.35A
Set by
model
○
36
F1.11
Self-learning
of
motor parameters
0: NO operation
1: complete tuning Self-learnin
2: static tuning Self-learning
0
×
37
F1.12
Speed loop
proportional gain1
0
~
100
30
○
38
F1.13
Speed loop integral
time1
0.01
~
10.00s
0.50s
○
39
F1.14
Switching low
point frequency
0.00Hz
~
F1.17
5.00Hz
○
40
F1.15
Speed loop
proportional gain 2
0
~
100
10
○
41
F1.16
Speed loop integral
time 2
0.01
~
10.00s
1.00s
○
42
F1.17
Speed loop integral
time 2
F1.14
~
F0.04
10.00Hz
○
43
F1.18
VC slip
compensating
factor
50%
~
200%
100%
○
44
F1.19
Upper torque limit
setting
0.0
~
200.0% (inverter rated current)
150.0%
○
45
F1.20
V/F curve setting
0: Linear V/F curve
1: square torque V/F curve
0
×
46
F1.21
Torque boost
0.0%(auto) 0.1%
~
30.0%
0.0%
○
47
F1.22
Torque boost
cut-off
0.0
~
80.0% (relative to motor rated frequency)
60.0%
×
48
F1.23
V/F slip
compensation limit
0.0
~
200.0%
0
○
49
F1.24
Energy
0: No Operation
0
○
50
Содержание ACD320 Series
Страница 1: ......
Страница 26: ...ACD320user manual Installation and wiring 21 11 30KW...
Страница 120: ...ACD320user manual Fault Diagnosis and countermeasures 115 1 Inverting module protection U 01...
Страница 124: ...ACD320user manual Fault Diagnosis and countermeasures 119 8 Under voltage U 09 9 InverterOver Load U 10...
Страница 126: ...ACD320user manual Fault Diagnosis and countermeasures 121 13 Inverting Module Over Heat U 14 14 External Failure U 15...
Страница 160: ......