![K&R ACD320 Series Скачать руководство пользователя страница 113](http://html1.mh-extra.com/html/kandr/acd320-series/acd320-series_user-manual_3099779113.webp)
ACD320 user manual
Parameter Description
- 108-
motor
3
Output voltage
0 to 150% of the rated voltage of
the motor
4
Running speed
0 to 200% of the rated running
speedof the motor
5
Output power
0 to 200% rated power of the motor
6
Output torque
0 to 200% of the rated current of the
motor
7
Analog value AVI
input
0
~
10V/0
~
20mA
8
Analog value ACI
input
0
~
10V/0
~
20mA
9
~
10
Reserved
Reserved
Function Code
Name
Setting Range
Default
Value
F9.10
AO2 analog output lower
limit
0.0%
~
100.0%
0.0%
F9.11
AO2 lower limit
corresponding analog
0.00
~
10.00V
0.0%
F9.12
AO2 analog output upper
limit
0.0%
~
100.0%
100.0%
F9.13
AO2 upper limit
corresponding analog
0.00V
~
10.00V
10.00V
The above function code defines the relationship between the output value and the analog
output corresponding value, the part of the output value that exceeding the maximum or
minimum output setting scope will be calculated according to the maximum or minimum output.
When analog output is the current output, 1mA current is equivalent to the 0.5V voltage.
In different applications, 100% of analog output corresponding to the output values are
different, please refer to the specific description of each application part.
Содержание ACD320 Series
Страница 1: ......
Страница 26: ...ACD320user manual Installation and wiring 21 11 30KW...
Страница 120: ...ACD320user manual Fault Diagnosis and countermeasures 115 1 Inverting module protection U 01...
Страница 124: ...ACD320user manual Fault Diagnosis and countermeasures 119 8 Under voltage U 09 9 InverterOver Load U 10...
Страница 126: ...ACD320user manual Fault Diagnosis and countermeasures 121 13 Inverting Module Over Heat U 14 14 External Failure U 15...
Страница 160: ......