Parameter Description
- 65-
Function Code
Name
Setting Range
Default
Value
F1.06
Motor stator
resistance
0.001
~
65.535Ω
Set by
model
F1.07
Motor rotor
resistance
0.001
~
65.535Ω
Set by
mode
F1.08
Motor stator/rotor
inductance
0.1
~
6553.5mH
Set by
mode
F1.09
Mutual inductance of
motor stator/rotor
0.1
~
6553.5mH
Set by
mode
F1.10
No-load current
0.01
~
655.35A
Set by
mode
After the motor self-learning is normally ended, F1.06-F1.10 setting values are
automatically replaced. These parameters are the basis of high performance vector control and
have direct effect on the control performance.
Important: users DO NOT change this group parameters at will.
Function Code
Name
Setting Range
Default
Value
F1.11
Self-learning of motor
parameters
0:NOoperation
0
1: complete tuning
Self-learning
2: static tuning
Self-learning
Note:This function is invalid for ACD200Seriess.
0: NO operation, forbidding self-learning.
1: self-learning of parameters
Prior to parameters self-learning, the motor must be disconnected with its load-ensuring the
motor at no-load condition, and confirming the motor is at static state.
Prior to parameters self-learning, it is a must to correctly input the motor nameplate
parameters(F1.01~F1.05), otherwise what is self learned about motor parameters may be not
correct.
Prior to parameters self-learning, theAcceleration and Deceleration time (F0.08 and F0.09)
should be set properly based on the motor inertia, otherwise over current fault may happen
during motor parameters self-learning.
When the self-learning of motor parameters is started by setting F1.11 as 1 and then pushing
the button FUNC/DATA, LED displays -TUN- and flickering, then push the button RUN to
Содержание ACD320 Series
Страница 1: ......
Страница 26: ...ACD320user manual Installation and wiring 21 11 30KW...
Страница 120: ...ACD320user manual Fault Diagnosis and countermeasures 115 1 Inverting module protection U 01...
Страница 124: ...ACD320user manual Fault Diagnosis and countermeasures 119 8 Under voltage U 09 9 InverterOver Load U 10...
Страница 126: ...ACD320user manual Fault Diagnosis and countermeasures 121 13 Inverting Module Over Heat U 14 14 External Failure U 15...
Страница 160: ......