MX10008 Installation Overview
The MX10008 is a rigid sheet-metal router-chassis that houses the other hardware components such as
RCBs, Switch Fabric Boards (SFBs), power supplies, fan trays, and line cards. The router chassis ships in a
cardbox box that has a two-layer wooden pallet base. The router chassis is bolted to the pallet base. You
can install an MX10008 router in a standard 19 in. (483 mm) equipment rack by using the supplied rack
mount kit and the flange that is attached to the chassis.
To install the MX10008:
1. Unpack the router following the instructions in
“Unpacking the MX10008” on page 132
2. Mount the chassis in the rack following either the instructions in
“Manually Mounting an MX10008 in
or in
“Mounting an MX10008 in a 4-Post Rack Using a Mechanical Lift” on
WARNING:
Because of the weight of the chassis, mounting using a mechanical lift
is preferred as the easiest and safest method.
3. Install the line cards following the instructions in
“Installing an MPC” on page 259
4. Connect the chassis to earth ground by following the instructions in
“Connecting an MX10000 to Earth
5. Connect power to the power supplies following either the instructions in
or
“Connecting DC Power to an MX10000” on page 164
.
6. Connect to the network.
•
To connect the router to a network for out-of-band management, follow instructions in
an MX10008 to a Network for Out-of-Band Management” on page 165
.
•
To connect the router to a management console, follow instructions in Connecting a Device to a
Management Console by Using an RJ-45 Connector.
7. Configure the router by following the instructions in
“Configuring an MX10008 Router” on page 167
.
8. Install optional equipment such as the cable management system. See
“Installing the Cable Management
131
Содержание MX10008
Страница 1: ...MX10008 Universal Routing Platform Hardware Guide Published 2019 11 11 ...
Страница 19: ......
Страница 89: ......
Страница 129: ......
Страница 170: ......
Страница 179: ...Figure 76 Removing Fan Tray JNP10008 FAN from an MX10008 FAN FTC SIB STATUS FAN FTC SIB STATUS 181 ...
Страница 183: ...Figure 79 Installing Fan Tray JNP10008 FAN in an MX10008 FAN FTC SIB STATUS FAN FTC SIB STATUS 185 ...
Страница 278: ...5 CHAPTER Troubleshooting Hardware Restoring Junos OS 283 Alarm Messages 287 ...
Страница 279: ......
Страница 287: ......
Страница 318: ...Restricted Access Warning 321 ...
Страница 333: ...Jewelry Removal Warning 336 ...
Страница 336: ...Operating Temperature Warning 339 ...
Страница 345: ...DC Power Disconnection Warning 348 ...
Страница 349: ...DC Power Wiring Sequence Warning 352 ...
Страница 352: ...DC Power Wiring Terminations Warning 355 ...
Страница 361: ...Translation The emitted sound pressure is below 92 dB A per GR63 CORE 364 ...