For other alarms not on the list, for persistent problems or for those different from the ones described above, please
contact Technical Assistance.
NUMBER ALARM NAME
CAUSE
MAIN REASONS
MAIN REMEDIES
•
The combustion chamber door
was left open during the start-up
phase
•
The PELLET hopper is empty
•
Check the PELLET load level in
the hopper.
•
Contact the CAT if this type of
alarm is tripped frequently
AL6
NO PELLETS
•
The temperature
falls below the TH-
RESHOL WORK set-
ting whilst the stove is
running.
•
There are no PELLETS in the
hopper
•
The level of PELLETS is so
low that the flame can not stay
alight.
•
The THRESHOL WORK set-
ting has been changed and the
trigger level is far too high
•
Check that the level of PEL-
LETS inside the hopper is suf-
ficient
•
Check the PELLET load times
are set correctly
•
Check the THRESHOL WORK
setting
•
It may be necessary to load
the pellets again from Menu
07 before restarting the stove.
The complete emptying of the
hopper usually involves the
emptying of the load auger too;
this will lead to a start-up with
insufficient pellets and trigger
a NO LIGHTIN- alarm. After
completing the Load Pellet se-
quence in Menu 7, the firebox
must be emptied, i.e. the stove
must be started up with a clean
firebox.
•
Contact the CAT if this type
of alarm is tripped frequently
AL7
SAFETY
THERMAL
•
Tripped thermal sa-
fety switch
•
The stove has overheated cau-
sed by:
- exchange fan is not working
- excessive PELLET load
- very dirty stove
•
The thermal safety switch is bro-
ken
•
The thermal safety switch wiring
is incorrect or disconnected.
•
Check that the exchange fan is
working properly
•
Check to see if the stove is dirty,
and clean it if necessary
•
Check the value of the load PEL-
LET settings
•
Check that the safety thermostat
and relative electrical connec-
tions are all intact
•
Contact the CAT if this type of
alarm is tripped frequently
AL8
FAILURE
DEPRESS
•
Tripped safety de-
pressimeter.
• The flue is clogged.
•
The depressimeter is broken.
•
Incorrect electrical wiring.
•
Incorrect silicon pipe connection
•
Check to see if the combustion
product exhaust duct is blocked.
•
Check the component is intact
and the relative electrical con-
nections correspond to the elec-
trical wiring layout
•
The silicon pipe is not connected
to connector H.
•
Contact the CAT if this type of
alarm is tripped frequently