Sample program - Real-time clock
Read the actual time and date of the JVM-407B and have the values
displayed.
An application program task reads out the real-time clock at regular intervals.
Then it outputs the readings properly formatted as trace message.
When you activate the trace mode in JetSym, JetSym displays these
readings.
The sample program has been tested for compliance with the following
software versions:
JetSym version 5.1
HMI JVM-407B, OS version 4.01
For more information on programming by STX, please turn to the online help
in JetSym.
Type
// Structure of the RTC buffer
TimeAndDate:
Struct
Second: Int;
Minute: Int;
Hour: Int;
DayOfWeek: Int;
Day: Int;
Month: Int;
Year: Int;
Trigger: Int;
End_Struct
;
End_Type
;
Var
RTCregs: TimeAndDate
At
%VL
102921
;
End_Var
;
Task
ShowTimeAndDate
Autorun
Var
Dummy: Int;
End_Var
;
Loop
// One second delay time
Delay(
T#1s
);
// Copying current time and current date into RTC buffer
Dummy := RTCregs.Trigger;
Task
Solution
Software versions
JetSym STX program
Содержание JVM-407B-HMI
Страница 1: ...User Manual JVM 407B HMI 60879892 We automate your success...
Страница 14: ......
Страница 26: ...26 Jetter AG 2 Product description and design Rear view...
Страница 34: ......
Страница 80: ......
Страница 98: ...98 Jetter AG 5 Initial commissioning Initial commissioning in JetViewSoft see page 86 Related topics...
Страница 106: ......
Страница 144: ......
Страница 168: ......
Страница 178: ......
Страница 182: ......
Страница 196: ...196 Jetter AG 10 Programming If Merker1 Then Inc Status_LEDs Delay T 100ms End_If End_Loop End_Task...
Страница 220: ...220 Jetter AG 10 Programming Topic Page Programming 221 Registers 233 Sample programs 238 Contents...
Страница 258: ......
Страница 268: ......
Страница 274: ......
Страница 294: ...294 Jetter AG Appendix Rear view...
Страница 299: ......