Chapter 6 DTF Testing
56
CellAdvisor JD720C User's Manual
Figure 26
Band list window
Distance
You can also manually set a distance to be measured by entering start and stop distances.
The maximum measurable distance is dependent on the frequency you set. You can set any
values within the maximum measurable distance, but optimum resolution is achieved when
you set the distance same as the maximum measurable distance, which is displayed in the
measurement setting information bar at the bottom of the measurement screen.
Procedure
1
Press the
SETUP
hard key and touch the
Frequency/Distance
tab.
2
Select the cell next to the
Start Distance
. Use the numeric keys or the rotary knob to change the
start distance value.
3
Select the cell next to the
Stop Distance
. Use the numeric keys or the rotary knob to change the
stop distance value.
4
Tap the
Apply
button in the lower-right corner of the setup screen to save the change(s).
Amplitude
You can set maximum and minimum values of the Y-scale manually by setting the Top and
Bottom amplitudes or restore the instrument's default full scale defined for each
measurement mode. You can also optimize the Y-scale automatically so that an entire trace
can be displayed on the measurement chart. Adjusting Y-scale does not affect calibration
status.
Procedure
1
Press the
SETUP
hard key and touch the
Amplitude
tab.
2
Do one of the following:
–
To set the
Top
and
Bottom
amplitudes manually, complete the following steps:
a
Select the cell next to the
Top
.