Error handling
Copyright IXXAT Automation GmbH
133
IEM Manual, 1.5
0xb060102b
EMI_k_DATASTRUCTURE_VERIFY_I
NV4
This error means that the service data is bigger than in
SD Queue MC->HC specified
FATAL
43
1
6.5.7 COM_k_UNIT_ID_HC_FUPH (unit id 7)
Error Code
Define
Description
Error
Class
Unit
Err
File
ID
0xb0701000
FUPM_k_SHM_INIT_VERS
This error means that the initialization failed because of
an invalid FUP version.
FATAL
0
1
0xb0701001
FUPH_k_ERR_BRD_REF_SHM_INF
O
The FUPH_AcsShmHostSegmentGetInfo() function was
called with an invalid IEM board number.
FATAL
1
1
0x30701002
FUPH_k_ERR_DST_PTR_NULL
The FUPH_AcsShmHostSegmentRead() function was
called with invalid destination pointer (pv_destination =
NULL).
FATAL
2
1
0x30701003
FUPH_k_ERR_SCR_PTR_NULL
The FUPH_AcsShmHostSegmentRead() function was
called with invalid source pointer (pv_source = NULL).
FATAL
3
1
0xb0701004
FUPH_k_ERR_ADDR_RANGE_STAR
T
The FUPH_AcsShmHostSegmentRead() function was
called with a source pointer out of the Host firmware
segment(too low).
FATAL
4
1
0xb0701005
FUPH_k_ERR_ADDR_RANGE_SIZE
The FUPH_AcsShmHostSegmentRead() function was
called with a source p size out of the Host firm-
ware segment (too high).
FATAL
5
1
0xb0701006
FUPH_k_ERR_CALL_CONTEXT
The FUPH_AcsShmHostSegmentRead() function was
called with an invalid segment status.
FATAL
6
1
0x30701007
FUPH_k_ERR_SEG_CRC
CRC of the segment delivered by the NIOS is wrong.
FATAL
7
1
0xa0701008
FUPH_k_ERR_CRC
CRC of the segment delivered by the NIOS is wrong. Call
the FUPH_ControlSmContinue() API function to repeat
the transmission of the segment with the wrong CRC.
Otherwise the HOST and NIOS processors must be
reinitialized, because the whole shared memory was
overwritten.
MINOR
8
1
0xb0701009
FUPH_k_ERR_SEG_REPEAT
The FUPH_ControlSmContinue() API function was called
in wrong context. The segment retransmission can not be
execute in current the segment status.
FATAL
9
1
0xb070100a
FUPM_k_SHM_RD_CLBK
This error means that the application callback function
indicated an error during the reading of a Host segment.
FATAL
10
1
0xb070100b
FUPM_k_SHM_SEG_STATUS
This error means that the status during Host segment
transmit is invalid.
FATAL
11
1
0xb0701064
FUPH_k_ERR_BCC_RESP_READ_A
CS
BCC response read access failed.
FATAL
100
1
0xb0702064
FUPH_k_ERR_BCC_RESP_READ_A
CS
BCC response read access failed.
FATAL
100
2
0xb0701065
FUPH_k_ERR_BCC_REQ_TIMEOUT
BCC request transmission timeout happened. BCC chan-
nel is blocked.
FATAL
101
1
0xb0702065
FUPH_k_ERR_BCC_REQ_TIMEOUT
BCC request transmission timeout happened. BCC chan-
nel is blocked.
FATAL
101
2
0xb0701066
FUPH_k_ERR_BCC_RESP_TIMEOU
T
BCC response reception timeout happened.
FATAL
102
1
0xb0702066
FUPH_k_ERR_BCC_RESP_TIMEOU
T
BCC response reception timeout happened.
FATAL
102
2
0xb07010c8
FUPH_k_ERR_PARSE_FUP_TYPE
Unknown firmware update type was received via the BCC
channel after the firmware update file was parsed.
FATAL
200
1
0xb07060c8
FUPH_k_ERR_PARSE_FUP_TYPE
Unknown firmware update type was received via the BCC
channel after the firmware update file was parsed.
FATAL
200
6
0xb070112c
FUPH_k_ERR_BRD_REF_RESET
The FUPH_ControlSmReset() function was called with an
invalid IEM board number.
FATAL
300
1
0xb070312c
FUPH_k_ERR_BRD_REF_RESET
The FUPH_ControlSmReset() function was called with an
invalid IEM board number.
FATAL
300
3
0xb070112d
FUPH_k_ERR_BRD_REF_CONT
The FUPH_ControlSmContinue() function was called with
an invalid IEM board number.
FATAL
301
1
0xb070312d
FUPH_k_ERR_BRD_REF_CONT
The FUPH_ControlSmContinue() function was called with
an invalid IEM board number.
FATAL
301
3
0xb070112e
FUPH_k_ERR_CLBCK_NOT_REGIS
TERED
The FUPH_EventToApp() function was called but
callback function was not registered.
FATAL
302
1
0xb070312e
FUPH_k_ERR_CLBCK_NOT_REGIS
TERED
The FUPH_EventToApp() function was called but
callback function was not registered.
FATAL
302
3
0xb070112f
FUPH_k_ERR_BRD_REF_POLL
The FUPH_ControlSmPoll() function was called with an
invalid IEM board number.
FATAL
303
1