Installation
Model API 3171 Installation, Operation, and Maintenance Manual
20
Support plate
type
Action
Tank flange
Install the supplied gasket between the two flanges. Make sure that the mating
flange on the tank is level. Use gasket material between the flanges in order to
make minor adjustments.
Figure 9: Layout for a standard support plate with the vapor-proof option
4. Hand tighten the anchor bolts. Check the level and re-shim if necessary.
5. Tighten all anchor bolts in a star pattern in order to avoid distorting the support plate.
Stuffing box installation
This pump is a sealless design. Therefore, when temperatures exceed 82°C | 180°F , you must
move the thrust bearing away from the heat source in the pump by adding the upper stuffing
box. Air can then circulate around the bearing in order to keep it cool.
The upper stuffing box is also used to minimize vapor emissions when the pump handles
controlled substances.
1. Motor support
2. Upper stuffing box
3. Gasket
4. Discharge pipe
5. Support plate
6. Gasket
Содержание Goulds Pumps API 3171