Maintenance
Model API 3171 Installation, Operation, and Maintenance Manual
41
disengagement of the holding clips prior to operation, allowing the seal to slide into place. If the
seal has been installed in the pump by ITT, these clips have already been disengaged.
Other mechanical seal types
For other types of mechanical seals, refer to the instructions provided by the seal manufacturer
for installation and setting.
Reference drawing
The manufacturer supplies a reference drawing with the data package. Keep this drawing for
future use when you perform maintenance and seal adjustments. The seal drawing specifies
the required flush fluid and attachment points.
Before you start the pump
Check the seal and all flush piping.
If the pump is shipped with oil-lubricated seals, keep the seal faces lubricated with oil at all
times.
Packed stuffing-box maintenance
WARNING:
•
Packed stuffing boxes are not allowed in an ATEX-classified environment.
• Failure to disconnect and lock out driver power may result in serious physical injury. Never
attempt to replace the packing until the driver is properly locked out.
Lubrication intervals
The lubrication intervals vary and depend upon the temperature and gland tightness. Keep the
grease cup full at all times.
Periodically make several turns on the grease-cup cap while you inject fresh grease into the
stuffing box. Check the pump daily upon initial operation, and extend this interval as required.
NOTICE:
Do not over-tighten the stuffing box. Excessive pressure can wear out packing prematurely and
seriously damage the shaft.
Packing replacement
Replace the packing in this sequence:
1. Three rings of packing
2. Lantern ring
3. Two rings of packing
4. Gland