Commissioning, Startup, Operation, and Shutdown
Model API 3171 Installation, Operation, and Maintenance Manual
34
Pump priming
WARNING:
These pumps are not self priming and must be fully primed at all times during operation.
Loss of prime can lead to excessive heat and severe damage to the pump and seal.
CAUTION:
Do not run the pump dry.
Never start the pump until it has been properly primed. Fully submerge the pump casing prior to
starting the pump.
For dry pit/outside tank mount units:
1. Ensure the suction supply line has adequate fluid head to prime the pump.
2. Slowly open the suction valve.
Install the coupling guard
WARNING:
• Running a pump without safety devices exposes operators to risk of serious personal
injury or death. Never operate a unit unless appropriate safety devices (guards, etc.) are
properly installed.
• Failure to disconnect and lock out driver power may result in serious physical injury or
death. Always disconnect and lock out power to the driver before performing any
installation or maintenance tasks.
• Electrical connections must be made by certified electricians in compliance with all
international, national, state, and local rules.
• Refer to driver/coupling/gear manufacturer's installation and operation manuals (IOM)
for specific instructions and recommendations.
•
The coupling used in an Ex-classified environment must be properly certified and must
be constructed from a spark resistant material.
This pump is shipped without the coupling guard installed, because the motor and coupling are
also not installed.
1. Wrap the expanded metal shield (501) around the motor support.
2. Install the two guard springs (501L).