Maintenance
Model API 3171 Installation, Operation, and Maintenance Manual
50
If ...
Then...
You use the stuffing box
Attach the motor support (240) to the stuffing box with bolts
(370J).
You do not use the stuffing box
Attach the motor support (240) to the support plate (189) with
bolts (370J).
3. Attach the head column (192):
If...
Then...
You use the stuffing box
Attach the head column (192) to the stuffing box with bolts
(370M).
You do not use the stuffing box
Attach the head column (192) to the motor support with bolts
(370M).
Make sure that the vent holes are closer to the motor support.
Assemble the rotating element
CAUTION:
Two people should handle any shaft over 9 feet long. Improper handling can bend the shaft.
1. For all groups except S/ST, install the retaining ring (369A) on the shaft (122).
2. Install the thrust bearing (112) on the shaft.
There are several methods that you can use in order to install bearings. The recommended
method is to use an induction heater that heats as well as demagnetizes the bearing.