Product Description
Model API 3171 Installation, Operation, and Maintenance Manual
16
ATEX nameplate
Figure 6: ATEX nameplate
Nameplate field
Explanation
II
Group 2
2
Category 2
G/D
Pump can be used when gas and dust are present
T4
Temperature class
WARNING:
Use of equipment unsuitable for the environment can pose risks of ignition and/or explosion.
Ensure that the code classifications on the pump are compatible with the specific environment
in which the equipment is to be installed. If they are not compatible, do not operate the
equipment and contact an ITT representative before proceeding.
Permissible temperatures
Code
Maximum permissible surface
temperature
Maximum permissible liquid
temperature
T1
450°C | 842°F
372°C | 700°F
T2
300°C | 572°F
277°C | 530°F
T3
200°C | 392°F
177°C | 350°F
T4
135°C | 275°F
113°C | 235°F
T5
100°C | 212°F
Option not available
T6
85°C | 185°F
Option not available
NOTICE:
The code classification marked on the equipment must be in accordance with the specified
area where you plan to install the equipment. If it is not, contact your ITT representative before
you proceed.