Maintenance
Model API 3171 Installation, Operation, and Maintenance Manual
49
• Inspect the ball bearings to see if they are loose, rough, or noisy when you rotate them.
• Investigate any bearing damage to determine the cause. If the cause is not normal wear,
correct the issue before you return the pump to service.
• Inspect bearing shell (134) bore according to the dimensions in the Bearing fits and
tolerances - Thrust bearing fits table. Replace if dimensions exceed these values.
• Replace the lower grease seal (133) at every overhaul.
• Visually inspect for cracks and pits. Pay particular attention to the snap ring groove.
Bearing fits and tolerances
Table 6: Steady bearing tolerances
This table references the bearing fits and tolerances according to ISO 286 (ANSI/ABMA Standard 7) in
millimeters | inches.
Descripti
on
Bearing ID (pressed into
place)
Housing bore
Running clearance (1/2
diametrical clearance)
S/ST
M/MT
L
S/ST
M/MT
L
S/ST
M/MT
L
Carbon
28.753–2
8.804 |
1.132–1.
134
41.478–4
1.529 |
1.633–1.
635
57.353–5
7.404 |
2.258–2.
260
41.173–4
1.224 |
1.621–1.
623
53.873–5
3.924 |
2.121–2.
123
76.048–7
6.098 |
2.994–2.
996
0.140–0.
089 |
0.0055–0
.0035
0.152–0.
102 |
0.006–0.
004
0.165–0.
102 |
0.0065–0
.004
Bronze
28.677–2
8.727 |
1.129–1.
131
41.377–4
1.427 |
1.629–1.
631
57.302–5
7.353 |
2.256–2.
258
41.173–4
1.224 |
1.621–1.
623
53.873–5
3.924 |
2.121–2.
123
76.048–7
6.098 |
2.994–2.
996
0.102–1.
051 |
0.004–0.
002
0.102–1.
051 |
0.004–0.
002
0.140–0.
076 |
0.0055–0
.003
Fluted
elasto-
mer
28.600–2
8.702 |
1.126–1.
130
41.326–4
1.453 |
1.627–1.
632
57.226–5
7.328 |
2.253–2.
257
41.173–4
1.224 |
1.621–1.
623
53.873–5
3.924 |
2.121–2.
123
76.048–7
6.098 |
2.994–2.
996
0.089–0.
013 |
0.0035–0
.0005
0.114–0.
025 |
0.0045–0
.001
0.127–0.
102 |
0.005–0.
004
Rulon
28.753–2
8.804 |
1.132–1.
134
41.478–4
1.529 |
1.633–1.
635
57.353–5
7.404 |
2.258–2.
260
-
-
-
0.140–0.
089 |
0.0055–0
.0035
0.152–0.
102 |
0.006–0.
004
0.165–0.
102 |
0.0065–0
.004
Casing
collar
30.048–3
0.226 |
1.183–1.
190
42.621–4
2.799 |
1.678–1.
685
58.395–5
8.472 |
2.299–2.
306
45.999–4
6.126 |
1.811–1.
816
56.972–5
7.023 |
2.243–2.
245
82.372–8
2.423 |
3.243–3.
245
0.851–0.
737 |
0.0335–0
.029
0.787–0.
673 |
0.031–0.
0265
0.737–0.
622 |
0.029–0.
0245
Table 7: Thrust bearing fits
Group
Shaft OD
Shell ID
S/ST
25.0139/25.0038) |
0.9848/0.9844
62.0166/61.9989 |
2.4416/2.4409
M/MT
40.0177/40.0025 |
1.5755/1.5749
90.0227/89.9998 |
3.5442/3.5433
L
55.0164/55.0037 |
2.1660/2.1655
120.0226/119.9896 |
4.7253/4.7240
Shaft runout tolerances
The following shaft runout tolerances apply to all size groups:
• Coupling end: 0.051 mm | 0.002 in.
• Shaft body: 0.0005 in./ft.
• Impeller end: 0.127 mm | 0.005 in.
Reassembly
Assemble the column and support plate
1. If you use the optional stuffing box, then attach the stuffing box (221) to support plate (189)
with bolts (370L).
2. Attach the motor support (240):
Содержание Goulds Pumps API 3171
Страница 1: ...Installation Operation and Maintenance Manual Model API 3171 ...
Страница 2: ......
Страница 63: ......