Maintenance
Model API 3171 Installation, Operation, and Maintenance Manual
52
5. Check the axial travel of the impeller.
If the travel is less than 0.762 mm | 0.030 in., then add extra gaskets (351) in order to
obtain the minimum travel.
6. Install the discharge elbow gasket (351A) and the discharge elbow (315) using bolts
(370H).
Accurate alignment of the elbow is critical in order to make sure that there is no obstruction
to the flow through the connection.
7. Install the discharge pipe (195), pipe nuts (242), and flange (195S, if used).
Make sure that the pipe nuts are tight and that there is no strain on the pump.
8. Rotate the shaft by hand in order to make sure that there is no binding.
9. Connect all auxiliary piping.
10. Replace the pump half coupling hub (233) and lubricate the pump bearings.
Содержание Goulds Pumps API 3171
Страница 1: ...Installation Operation and Maintenance Manual Model API 3171 ...
Страница 2: ......
Страница 63: ......