Cool liquid flushing method Description
External source
A clean, cool, compatible liquid is injected from an outside source directly into the seal gland.
Flushing liquid must be at a pressure 5–15 psi (0.34–1.03 bar) greater than the pressure in
the stuffing box. You must inject 1.5–2 gpm (2–8 lpm). You can install a control valve and
rotometer in the inlet line for accurate regulation.
Product cooling
Pumped liquid is piped from the pump casing, is cooled in an external heat exchanger, and is
injected into the seal gland. You can install a control valve and rotometer in the inlet line for
accurate regulation.
Other piping plans are available.
5.14 Connection of drain piping
Tapped openings around the stuffing box for draining leakage are optional. Check the assembly dimen-
sion print for size and location. Check the rotor for free turning.
WARNING:
Explosion risk. Rubbing could lead to excess heat generation and sparks. Rotate the shaft by
hand to make sure it rotates smoothly and that there is no rubbing.
5.15 Pump priming
CAUTION:
Do not run the pump dry.
When to prime the pump
You must prime the pump before startup. When it is possible, locate the pump below the fluid
level in order to facilitate priming and to ensure a steady flow of liquid. This condition provides a positive
suction head on the pump. It is also possible to prime the pump by pressurizing the suction vessel.
Methods for pump priming
Pump installation
Priming method
Positive head on the suction
Open the suction valve and loosen the vent plug on top of the cas-
ing. This allows air to be purged from the casing. While you vent the
air from the pump body, always rotate the pump shaft a few times by
hand.
Suction lift
Priming must be done by other methods such as foot valves, ejec-
tors, or by manually filling the casing and suction line.
5.16 Start the pump
1.
Close the drain valves.
2.
Completely open all valves in the suction and discharge lines.
3.
Turn on the seal water to the stuffing box.
These lines must always be left open if the pumped fluid is dirty or if there is the possibility of air
leaks.
5.14 Connection of drain piping
Model 3410 Installation, Operation, and Maintenance Manual