5.8.2 Lubricate the bearings with oil (optional)
NOTICE:
•
The bar must be adjusted as stated in this procedure. Otherwise, the bearing will not be
lubricated.
•
Do not fill the oil reservoir of the bearing frame through the plug at the top.
Oil-lubricated pumps are not lubricated at factory. Use a high quality, turbine-type oil with rust and oxida-
tion inhibitors. Constant level oilers are supplied in the box of fittings that accompanies most oil-lubricat-
ed pumps. Make oil adjustments before lubrication. See
6.3.2.1 Lubricating-oil requirements on page 57
for recommended lubricants and supplies.
Bearing cooling is available with the oil lubrication option only. Cooling water must be connected to the
bearing housing with a waste or return line. Water cooling is required when operating temperatures ex-
ceed 121°C | 250°F.
1.
Remove the oiler.
1
2
3
A
B
1.
Oiler
2.
Adjustment assembly
3.
Housing
2.
Remove the adjustment assembly from the oiler.
3.
Adjust the bars to dimension A as specified in
5.8.3 Bar adjustment on page 44
4.
Lock in position.
5.
Replace the adjustment assembly in the oiler.
6.
Install the oiler.
7.
Fill each bottle with oil and replace in the oiler housing.
The oil reservoir in the bearing housing is filled when the oil remains visible in the bottle. You will
need to fill the bottle several times.
5.8.3 Bar adjustment
Specification
Measurement
Dimension A
14.5 mm | 9/16 in.
Dimension B
13 mm | 1/2 in.
Oiler size
204 ml | #5 8 oz
Casing capacity
•
S and M groups: 266 ml | 9 oz
•
L and XL groups: 489 ml | 16.5 oz
5.8 Bearing lubrication
44
Model 3410 Installation, Operation, and Maintenance Manual