1
1.
Air pocket
Figure 19: Suction pipe installed with a gradual rise to the pump – incorrect
1
1.
Air pocket
Figure 20: Suction pipe installed with a reducer – incorrect
1
1.
Air pocket
Figure 21: Incorrect
2
1
1.
No air pockets
2.
Gradual rise
Figure 22: Correct
3
2
1
1.
No air pockets
2.
Eccentric reducer
3.
Gradual rise
Figure 23: Gradual rise to the pump – correct
1
1.
Distance plus eccentric reducer straightens the flow
Figure 24: Suction pipe above the pump – correct
4.5 Piping checklists