1.
Nylon sling, chain, or wire rope
2.
Do not lift the entire pump with these lugs
3.
Choker hitch around the bearing frame
Figure 2: The proper lifting method for a horizontal bare pump
45° max
L
2
L
Figure 3: The proper lifting method for a horizontal pump on a base with lifting holes
45° max
L
2
L
Figure 4: The proper lifting method for a horizontal pump on a base without lifting holes
Pumps mounted vertically
Pump mounting
Lifting method
Half pedestal
Place a nylon sling chain or wire rope around both flanges. Use a latch hook
or standard shackle and end loops. Be sure the lifting equipment is long
enough to keep the lift angle less than 30° from the vertical.
Full pedestal
Install eyebolts in the three holes provided at the top of the support and tight-
en securely. Attach a chain or wire rope using a latch hook or standard shack-
le and end loop. You must use shoulder eyebolts that are manufactured per
ANSI B18.15 and sized to fit the holes provided. Be sure the lifting equipment
is long enough to keep the lift angle less than 30° from the vertical.
2.2 Transportation guidelines