5.7 Couple the pump and driver
WARNING:
Failure to disconnect and lock out driver power may result in serious physical injury or death.
Always disconnect and lock out power to the driver before performing any installation or main-
tenance tasks.
•
Electrical connections must be made by certified electricians in compliance with all inter-
national, national, state, and local rules.
•
Refer to driver/coupling/gear manufacturer's installation and operation manuals (IOM) for
specific instructions and recommendations.
CAUTION:
•
The coupling guard used in an ATEX classified environment must be properly
certified and constructed from a spark resistant material.
•
Running a pump without safety devices exposes operators to risk of serious personal in-
jury or death. Never operate a unit unless appropriate safety devices (guards, etc.) are
properly installed.
Couplings must have proper certification to be used in an ATEX classified environment. Use
the instructions from the coupling manufacturer in order to lubricate and install the coupling. Refer to
driver/coupling/gear manufacturers IOM for specific instructions and recommendations.
5.8 Bearing lubrication
CAUTION:
•
Risk of explosive hazard and premature failure from sparks and heat genera-
tion. Ensure bearings are properly lubricated prior to startup.
•
Risk of heat generation, sparks and premature failure. Do not insulate bearing housings.
5.8.1 Lubricate the bearings with grease
Grease-lubricated pumps can be identified by grease fittings located on bearing housing. Sufficient lubri-
cant is inserted at the factory for 2,000 hours of operation. See the Maintenance chapter for grease lubri-
cation instructions.
5.7 Couple the pump and driver
Model 3410 Installation, Operation, and Maintenance Manual
43