Troubleshooting
Introduction
Follow these guidelines when troubleshooting the pump:
• Disconnect and lock out the power supply except when conducting checks that require voltage.
• Make sure that no one is near the pump when the power supply is reconnected.
• When troubleshooting electrical equipment, use the following:
• Universal instrument multimeter
• Test lamp (continuity tester)
• Wiring diagram
The pump does not start
WARNING:
Always disconnect and lock out power before servicing to prevent unexpected startup. Failure to do so
could result in death or serious injury.
NOTICE:
Do NOT override the motor protection repeatedly if it has tripped. Doing so may result in equipment damage.
Cause
Remedy
An alarm signal has been triggered
on the control panel.
Check that:
• The impeller rotates freely.
• The sensor indicators do not indicate an alarm.
• The overload protection is not tripped.
If the problem still persists:
Contact the local ITT service shop.
The pump does not start
automatically, but can be started
manually.
Check that:
• The start level regulator is functioning. Clean or replace if necessary.
• All connections are intact.
• The relay and contactor coils are intact.
• The control switch (Man/Auto) makes contact in both positions.
Check the control circuit and functions.
The installation is not receiving
voltage.
Check that:
• The main power switch is on.
• There is control voltage to the start equipment.
• The fuses are intact.
• There is voltage in all phases of the supply line.
• All fuses have power and that they are securely fastened to the fuse
holders.
• The overload protection is not tripped.
• The motor cable is not damaged.
The impeller is stuck.
Clean:
• The impeller
• The sump in order to prevent the impeller from clogging again.
If the problem persists, refer to the Flygt Service Guide on the web or contact the local ITT service shop.
Always state the serial number of your pump when you contact ITT, see
(page 8).
Troubleshooting
60
Flygt 3102 Service and Repair Instructions
Содержание Flygt 3102
Страница 1: ...Water Wastewater Service and Repair Instructions Flygt 3102...
Страница 2: ......
Страница 67: ...Figure 13 3201 170 Technical Reference Continued Flygt 3102 Service and Repair Instructions 65...
Страница 68: ...Figure 14 3201 180 3201 185 Technical Reference Continued 66 Flygt 3102 Service and Repair Instructions...
Страница 71: ......