4. Fit the impeller puller and pull off the impeller and cutter wheel.
Place a protector between the screw head and the impeller puller.
5. Remove the conical sleeve.
Install the M-impeller
1. Make sure that the end of the shaft is clean and free from burrs.
Polish off any flaws with a fine emery cloth.
2. Mount the impeller:
a) Fit the conical sleeve onto the shaft.