4. If applicable, fit the sliding bracket.
Replace the impeller
Required tools:
• 8 mm hexagon bit adapter with an extension of at least 125 mm (4.92 in.)
• Impeller puller
If applicable, contact your local ITT representative for correct type and size.
• Rod (wooden or copper) for locking the impeller in place, if applicable.
• Two crowbars, if applicable
WARNING:
• If you fail with the impeller installation, you must redo the installation procedure from the beginning.
• A worn impeller and/or pump housing can have very sharp edges. Wear protective gloves.
• When laying the pump on its side, do not allow the weight of the pump to rest on any portion of the
impeller. The impeller must not be allowed to make contact with the concrete floor or other hard and
rough surfaces.
Maintenance (Continued)
42
Flygt 3102 Service and Repair Instructions