3. Mount the pump housing:
a) Fit the pump housing.
b) Fit and tighten the lubricated screws.
Tightening torque: 57 Nm (42 ft-lbs).
4. Adjust the impeller:
a) Measure the distance between the lower edge of the impeller and the insert ring.
The correct distance is 0.2-0.8 mm (0.084-0.032 in.).
b) Slide the impeller on the shaft until the correct clearance is reached.
5. Tighten the impeller screw.
If applicable, use the rod.
Tightening torque: 65 Nm (48 ft-lbs)
Check that the impeller can rotate freely.
CAUTION:
Beware of the pinch point hazard between the rotating impeller and the guide pin.
Maintenance (Continued)
56
Flygt 3102 Service and Repair Instructions
Содержание Flygt 3102
Страница 1: ...Water Wastewater Service and Repair Instructions Flygt 3102...
Страница 2: ......
Страница 67: ...Figure 13 3201 170 Technical Reference Continued Flygt 3102 Service and Repair Instructions 65...
Страница 68: ...Figure 14 3201 180 3201 185 Technical Reference Continued 66 Flygt 3102 Service and Repair Instructions...
Страница 71: ......