Check that the impeller can rotate freely.
4. Adjust the impeller:
a) Measure the distance between the edge of the impeller and the pump housing cover.
The correct distance should be 0.5-1.5 mm (0.02-0.06 in.). Add or remove the appropriate number
of adjusting washers in order to achieve correct distance.
b) Tighten the impeller screw.
If applicable, use the rod.
Tightening torque: 65 Nm (48 ft-lbs)
Check that the impeller can rotate freely.
5. Fit a new greased O-ring to the into the groove in the pump housing.