The data plate
The data plate is a metal label located on the main body of the pump. The data plate lists key product
specifications. Explosion-proof products also have an approval plate. Both are described below.
2
13
12
14
22
21
20
17 18
19
16
15
9
10
11
8
7
6
5
4
3
1
23
24
1.
Curve code/Propeller code
2.
Serial number, see
(page 11)
3.
Product number
4.
Country of origin
5.
Additional information
6.
Phase; type of current; frequency
7.
Rated voltage
8.
Thermal protection
9.
Thermal class
10. Rated shaft power
11. International standard
12. Degree of protection
13. Rated current
14. Rated speed
15. Maximum submergence
16. Direction of rotation: L=left, R=right
17. Duty class
18. Duty factor
19. Product weight
20. Locked rotor code letter
21. Power factor
22. Maximum ambient temperature
23. Read installation manual
24. Notified body/only for EN-approved Ex-products
Figure 1: The data plate
Approvals
This section describes the EN and FM approvals that explosion-proof products have. For more
information, please contact your ITT representative. In addition to the data plate, explosion-proof
products also have either an EN or a FM approval plate.
EN
• European Norm
• ATEX Directive
• EN 50014, EN 50018, EN 1127-1
•
II 2 G EEx d IIB T4
Product Description (Continued)
Flygt 3102 Service and Repair Instructions
9
Содержание Flygt 3102
Страница 1: ...Water Wastewater Service and Repair Instructions Flygt 3102...
Страница 2: ......
Страница 67: ...Figure 13 3201 170 Technical Reference Continued Flygt 3102 Service and Repair Instructions 65...
Страница 68: ...Figure 14 3201 180 3201 185 Technical Reference Continued 66 Flygt 3102 Service and Repair Instructions...
Страница 71: ......