4. Refit the oil plug and tighten.
Tightening torque: 10-40 Nm (7.5-29.5 ft-lbs)
Disassemble the pump
Before the pump is disassembled the pump has to be drained of all coolant. For information, see
(page 23).
For specially approved drive units, follow the instructions in
Specially approved drive units
during the disassembly.
Follow the applicable instructions when removing the mechanical seal.
Remove the inner mechanical seal: Griploc
(page 29)
• For seals type T, see information included in the spare part.
• Other seals:
(page 27)
1.
Remove the motor cable and the stator housing
(page 25)
2.
(page 26)
3.
(page 27)
a)
Remove the outer mechanical seal: Griploc
(page 27)
b)
Remove the outer mechanical seal
(page 27)
c)
(page 28)
d)
Remove the inner mechanical seal: Griploc
(page 29)
e)
Remove the inner mechanical seal
(page 29)
4.
5.
Remove the stator from the stator housing
(page 30)
Remove the motor cable and the stator housing
1. Remove the stator housing:
a) Remove the stator housing screws.
b) Lift of the stator housing from the oil housing.
2. Open the entrance cover.