For instructions about how to remove the impeller, see
(page 42).
Remove the mechanical seal
Remove the outer mechanical seal: Griploc
1. Loosen the seal locking screw.
Use a 8 mm flat bladed screwdriver
2. Remove the rotating seal unit.
3. Remove the stationary seal ring including its O-ring.
Remove the outer mechanical seal
1. Remove the grip ring:
a) Fit the mounting tool and turn the allen key to release the grip ring.
Use the mounting tool.
b) Remove the grip ring.
Maintenance (Continued)
Flygt 3102 Service and Repair Instructions
27
Содержание Flygt 3102
Страница 1: ...Water Wastewater Service and Repair Instructions Flygt 3102...
Страница 2: ......
Страница 67: ...Figure 13 3201 170 Technical Reference Continued Flygt 3102 Service and Repair Instructions 65...
Страница 68: ...Figure 14 3201 180 3201 185 Technical Reference Continued 66 Flygt 3102 Service and Repair Instructions...
Страница 71: ......