2. Pull the stator leads into the junction box through the cable-lead-trough in the stator housing.
3. Connect the leads to the terminal board as shown in appropriate cable chart.
Check the insulation for the connections with a Megger. The insulation between the phases and
between any phase and earth must be > 5 MΩ.
4. Assemble and fasten the cable entry.
Make sure that the gland screw bottoms out when fasten.
Cable entry for cables with the
outside diameter of 12–20 mm
(0.47–0.79 in.)
Cable entry for cables with the outside diameter of (20)–32
mm ((0.79)–1.26 in.)
5. Lubricate and fit the O-ring on the bearing holder.
Push it down to the oil housing bottom.
Maintenance (Continued)
36
Flygt 3102 Service and Repair Instructions