3. Disconnect the motor cable and the stator leads from the terminal board.
4. Pull out the stator leads through the cable lead trough in the stator housing.
5. Undo the cable entry and pull the motor cable out of the entrance cover.
Inspect the cable for damage, especially close to the cable entry.
Remove the pump housing
1. Remove the pump housing screws.
2. Fasten lifting eye bolts in the oil housing screw holes.
Use M10 eye bolts.
3. Lift of the rotor assembly with the oil housing and impeller from the pump housing.
Maintenance (Continued)
26
Flygt 3102 Service and Repair Instructions
Содержание Flygt 3102
Страница 1: ...Water Wastewater Service and Repair Instructions Flygt 3102...
Страница 2: ......
Страница 67: ...Figure 13 3201 170 Technical Reference Continued Flygt 3102 Service and Repair Instructions 65...
Страница 68: ...Figure 14 3201 180 3201 185 Technical Reference Continued 66 Flygt 3102 Service and Repair Instructions...
Страница 71: ......