Fig. 4
7
2. INSTALLATION
2.1. PLATE DATA
•
•
•
Make sure that the plate data and electrical line features
correspond (V, kW, Hz, phase and available power).
The plate carrying the features of the appliance is
applied on the side (fig.2).
Remember also that the potential intervention of
safety valves or fuse caps in the refrigeration circuit
entails the immediate discharge of all the refrigerant used
in the ambient. Therefore make sure to realise opportune
means of waste disposal and first aide, as indicated on
the safety cards of the refrigerant (
see par. 2.12).
Climatic class:
4
(30°C room temperature with 55% non-condensing
relative humidity) according to Standards CEI EN
60335-1, CEI EN 60335-2-89, ISO 23953-2:2005(E)
Fig. 2
31020
CORBANESE (TV)
ITALY
Mod.
s/n
Compressor HERMETIC
V
A
Refrigerant R404 Charge
Desing pressure (Low)
Desing pressure (High)
Rated Load
Class
Volume
PED Code
IP
KPa
KPa
Kw
Ph
Hz
Model
Series n.
mm/yy/progres.
Frequency
Power
Phase
Absorption
Voltage
2.2. POSITIONING
•
•
•
•
•
•
•
•
The blast chiller must be installed and inspected in
complete compliance with accident-prevention Law
Standards, with traditional rules and with Standards
now in force.
The installer must check potential fire-prevention
prescriptions (contact the nearest fire station for the
due indications).
Place the blast chiller in the intended spot.
Level the appliance by means of the adjustment feet.
Use appropriate lifts to level heavier machinery (Fig.3).
If the appliances are not levelled, their operation and
condensation outflow can be jeopardised.
Fig. 3
If the blast chiller/conserver is installed below floor level
or underground, the installer must apply the clauses
foreseen by the standard EN378- 1:2008+A1:2010
ANNEX D to guarantee that no one can remain locked
inside the cell at the end of the work shift.
The blast chiller/conserver can be installed under-
ground or on a loft as long as there are adequate
emergency exits as foreseen by the standard EN378-
1:2008+A1:2010 ANNEX C.
The installer must verify the need for forced ventilation
inside a room where the blast chiller/conserver is installed
as foreseen by the standard EN378- 2:2008+A1:2009
chapter 6.2.14.
•
•
•
To be avoided (Fig.4):
Places exposed to direct sunlight
Closed places with high temperatures and scarce air
exchange (
see
Table 2
).
Do not install the machine near to any heat sources.