irinox ICY L Скачать руководство пользователя страница 20

20

3.6.3. Pre-cooling

3.6.2.  Loading the machine

Before a cycle of blast chilling and/or shock freezing, it 
is essential to pre-cool the chamber in order to further 
reduce work time. Therefore, before inserting the product
to be blast chilled, carry out an empty SOFT or HARD 
cycle.

Do not leave the hot product inside of the 
chamber, in order to avoid damaging the 
machine. As soon as the product to be 
treated is inserted, start the blast chilling 
or shock freezing cycle right away.

3.6.4.  Core probe

The core probe must be positioned correctly at the 
centre of the largest piece or cut of the product. Make 
sure that the point of the probe does not come out of the 
product or touch the tray. The probe must be cleaned 
and sanitised before each work cycle in order to avoid 
unwanted contamination.
For better results, load the GN1/1 containers with a 
product weighing 3.5 kg and with a maximum thickness 
of 8 cm for blast chilling, or 5 cm for shock freezing.
For difficult products and/or fats, reduce thickness even 
more.

If the machine is not loaded completely, concentrate 
the trays in the middle of the blast chiller, placing an 
empty tray (A) above the last one.

Position the trays in the innermost part of the tray-
holder, making sure that they are as close as possible 
to the evaporator.

Do not overload the machine beyond what the manufac-
turer has established (Tab. “Tray yield and capacity”).

A

Maximum load per shelf: 5 kg

MODELS

ICY S

ICY M

ICY L

Blast chilling (Kg)

Yield

CATERING

CONFECTIONERY

Shock freezing (Kg)

GN 1/1 h=20

18

38

45

15

35

38

8

18

27

GN 1/1 h=40

5

12

18

GN 1/1 h=65

4

9

13

400x600 h=20

8

18

27

400x600 h=40

5

12

18

400x600 h=50

4

9

13

The yield is stated at the following conditions:
- Trays filled with water at 90°C
- Room temperature: 32°C
- No chamber pre-cooling

Содержание ICY L

Страница 1: ...N REV REVISION DESCRIPTION DATE REV REVISER 00 FIRST EMISSION 01 12 2015 NC U S E A N D M A I N T E N A N C E I N S T R U C T I O N S...

Страница 2: ...ne easy and intuitive to use Symbols key suggestions and details for correct use of the blast chiller standards for your safety additional information in this manual Information regarding the warranty...

Страница 3: ...the power supply having a contact separation of all poles that pro vide disconnection in category III overvoltage conditions must be equipped with a disconnec tion device incorporated in the fixed con...

Страница 4: ...RATION POWER 9 2 6 ELECTRICAL CONNECTION 9 2 7 REFRIGERATOR CONNECTION 10 2 8 CONDENSATION DRAIN 10 2 9 SAFETY AND CONTROL SYSTEMS 10 2 10 SAFETY AND CONTROL SYSTEMS 11 2 11 DISPOSAL OF THE MACHINE 11...

Страница 5: ...n compliance with directive 97 23 EC based on the model the equipment is supplied together with the user manuals and declarations of conformity of the safety valve liquid receiver liquid separator liq...

Страница 6: ...op Extract the core probe s from the product and posi tion it them on the probe holder Use suitable gloves for cold trays and trolleys 1 7 DANGEROUS USE OF THE SHARP PROBE Use of the probe is allowed...

Страница 7: ...ent prevention Law Standards with traditional rules and with Standards now in force The installer must check potential fire prevention prescriptions contact the nearest fire station for the due indica...

Страница 8: ...474mm DRAIN PIPE 20mm DRAIN PIPE 20mm 400mm 383 mm 1475mm ICY S ICY M ICY L 383 mm 474mm AIR FLOW AIR FLOW Min 75 mm 774mm 884mm 89mm 187mm 68mm 68mm 1453mm min 70 mm min 30 mm 115mm 165mm 765mm 400mm...

Страница 9: ...ion cables must comply with the information contained in the electric data of the technical files The voltage of the plants must be within the limit of 10 and voltage unbalance of the phases must not...

Страница 10: ...ON DRAIN The blast chillers are equipped with a small tray to gather condensation The tray can put extracted from the bottom part of the Blast chiller For calibration of the R404a pressure switches se...

Страница 11: ...e 2011 65 CE 2012 19 UE and 2003 108 CE Directives relative to the reduction of use of dangerous substances in electric and electronic appliances as well as disposal of waste The barred bin symbol on...

Страница 12: ...ld burns It is improbable that it is dangerous due to cutaneous absorption Repeated and prolonged contact can cause the removal of sebaceous matter with consequent dryness cracking and dermatitis Ecol...

Страница 13: ...empera ture of 0 C In the second phase the core temperature of the product is brought to 18 C with an operation temperature that can reach 40 C This cycle is particularly indicated for shock freezing...

Страница 14: ...will have time to heat the compressor This avoids breakdown at the first turn on due to returning refrigerant liquid 1 Start the chosen cycle for at least 5 minutes before putting the hot food into t...

Страница 15: ...lity to increase or decrease the cycle time by pressing the plus and minus keys Press and hold for over two seconds to increase the time faster Press the key to start the selected cycle The timer cann...

Страница 16: ...the cycle Press to go back to the initial grid Press to put the screen in stand by while the cycle is active Do not use the Blast Chiller as a Holding Cabinet Open the Blast Chiller door extract the...

Страница 17: ...Press on the home screen to access the defrost mode Defrost cycle selection and start up Description Function 1 Use the keys shown on the display to change the time Press the key to start the selecte...

Страница 18: ...e print log 4 When the download is complete the display shows Completed If the download fails or the USB pen drive is not connected the display shows Error If you press the button during the download...

Страница 19: ...containers with a product weighing 3 5 kg and with a maximum thickness of 8 cm for blast chilling or 5 cm for shock freezing For difficult products and or fats reduce thickness even more Make sure to...

Страница 20: ...nation For better results load the GN1 1 containers with a product weighing 3 5 kg and with a maximum thickness of 8 cm for blast chilling or 5 cm for shock freezing For difficult products and or fats...

Страница 21: ...s for the cycles start at 90 C from 90 C to 3 C or the blast chilling cycle from 90 C to 18 C for the shock freezing cycle 3 6 6 Preservation Blast chilled and or shock frozen food must be properly co...

Страница 22: ...ed for the DELICATE 3 C cycle for the STRONG 3 C cycle for the DELICATE 18 C cycle for the STRONG 18 C cycle for the defrosting cycle The list of parameters that can be modified appears after selectin...

Страница 23: ...First stage end core temperature Cycle end core temperature Stage 1 blast chilling duration Stage 2 blast chilling duration Set Description Ris Default Notes 40 C 40 C 40 C 40 C 40 C 40 C 40 C 40 C 40...

Страница 24: ..._2 time 1 C 1 C 1 C 1 C 1 C 1min 1min 0 C 35 C 19 C 6 C 18 C 60 min 180 min First stage freezing air temperature Cycle end freezing air temperature First stage end core temperature Cycle end core temp...

Страница 25: ...Selection setting Recording frequency setting expressed in minutes Recording mode selection Machine number setting Print language selection Software release display 3 digits Key tone enabling Sanitisi...

Страница 26: ...ll in the atmosphere which is the vehicle of 97 of bacterial contaminations for food Absence of bacteria allows to obtain the following advan tages inside the chamber continuous sanitising of the insi...

Страница 27: ...plastic base 5 Clean the glass cylinder with a damp cloth Remove any dust deposits carefully 6 8 Insert the external net paying attention not to overlap the internal net and keep a distance of about...

Страница 28: ...er clockwise with the external net always acting on the red plastic base 1 Release the external tab holding the glass cylinder still 3 Dispose of the glass cylinder with the external net as dry waste...

Страница 29: ...cleaning or routine maintenance disconnect the machine from the power supply network turning off the master switch and pulling the plug do not pull the power cord to disconnect the machine from the po...

Страница 30: ...r to loosen the screw located at the right side of the fan holding panel and turn it to the left Do not use sharp objects METHODS FOR CLEANING EVAPORATOR In order to clean the evaporator a brush can b...

Страница 31: ...ped grid with force For remote condensing units the air condenser must be kept clean to allow free air flow This operation which must be carried out at least every 30 days can be done with non metalli...

Страница 32: ...oken Technician intervention Replace S1 probe Replace S2 probe Probes S1 and S2 are broken Possible cause Possible solution Description Phase Front panel screen RESETTING THE ALARM RECORDING MEMORY 1...

Страница 33: ...an to replace device Fan broken Intervention of a technician to replace fan Start condenser broken Intervention of a technician to replace start condenser Compressor remote switch consent missing Inte...

Страница 34: ...condensing plant where applicable Remove the rear protection grid by undoing the screws with a flat head screwdriver Fig 14 4 5 EXTRAORDINARY MAINTENANCE 4 5 1 How to access the front circuit board T...

Страница 35: ......

Страница 36: ...0 Corbanese di Tarzo TV Italy production site via Caduti nei lager 1 Z I Prealpi Trevigiane loc Scomigo 31015 Conegliano TV Italy P 39 0438 2020 F 39 0438 2023 irinox irinox com www irinoxprofessional...

Отзывы: